EcoDim Smart LED dimmer Z-Wave User Manual

EcoDim Smart LED dimmer Z-Wave User Manual & troubleshooting

EcoDim Smart LED dimmer Z-Wave User Manual  & troubleshooting 1EcoDim Smart LED dimmer Z-Wave User Manual  & troubleshooting 2
EcoDim Smart LED dimmer Z-Wave User Manual  & troubleshooting 3
USER MANUAL
Smart LED dimmer Z-Wave 0-200W
Eco-Dim.07 Z-Wave

Please read this manual carefully before installation.
Important!

  • It is dangerous if people without proper training work on an electrical installation!
  • There may be a dangerous voltage at the output of the dimmer!
  • When working on the wiring always switch off the mains voltage. Failure to observe this warning may result in death or serious injury!
  • Read the instructions carefully. Incorrect installation may damage the dimmer beyond repair.

Smart Dimmer Switch 200W LED Item NO. Eco-Dim.07 Z-Wave

EcoDim Smart LED dimmer Z-Wave User Manual  & troubleshooting 4

EcoDim Smart LED dimmer Z-Wave User Manual  & troubleshooting 5

  • Compatible with any Z-Wave or Z-Wave plus controller.
  • Power Consumption meter
  • Voice support (Amazon Alexa & Google Assistant / Homey)
  • Achieve the on/off and dimming function through separately physical button
  • Support Repeater Role, Firmware OTA and SmartStart.
  • Suitable for 0-200W LED
  • Suitable for all well-known brands of cover frames
  • Optimal dimmable & light stability
  • MIN and MAX light adjustment options
  • Suitable for 90% of all LEDs
  • Installation with provided 2 wires (no neutral wire required)
  • Soft start system
  • Noiseless dimming
  • Suitable for surface-mounted boxes & flush-mounted boxes with or without screw holes

Specifications

Input voltage 220-240 Vac, 50Hz
Power (load) 0-200W LED 10-300W Halogen light bulbs
Suitable for Led-, halogen-, light bulbs
Type dimmer R, C  Phase cut
Working temperature 35 °C
Operation Push/turn button
Dimensions 70.6×70.6x33mm
Weight 49,98g

Suitable brands of cover material:

  • Berker by Hager
  • Busch-Jaeger
  • Gira
  • JUNG
  • Kopp
  • Merten by Schneider
  • Niko
  • PEHA
EcoDim Smart LED dimmer Z-Wave User Manual  & troubleshooting 6 EcoDim Smart LED dimmer Z-Wave User Manual  & troubleshooting 7

Installation

Step 1: Remove the knob and the cover plate.
Step 2: Always make sure that the electricity is switched off during installation. Then connect the wires as indicated in the ‘Connection diagram’.
Step 3: Now install the dimmer in the mounting box. Use screws or tighten the screws of the mounting clamps.
Step 4: Switch the electricity back on. Switch on the connected lights by pressing the dimmer shaft. Now adjust the ‘MIN/MAX adjustment, as described  under ‘MIN/MAX installation’
Step 5: Optionally you may connect the dimmer to your SMART home system as indicated under the heading “Connecting home automation/apps”.
Step 6: Place back the cover plate and dimmer knob.

MIN/MAX adjustment

For the SMART dimmer to work optimally, you can adjust the lights to the dimmer with the MIN and MAX adjustment. As soon as you start turning MIN  and MAX adjustment, the dimmer will automatically go to the minimum and maximum light range.

MIN adjustment: Switch on the lights with the push/turn button. When the lights are on, insert a screwdriver in MIN and turn to the left. When the light becomes unsteady, turn slightly back to the right so that the light remains steady.

MAX adjustment: Switch on the lights with the push/turn button. When the lights are on, insert a screwdriver in MAX and turn to the right. When the light becomes unsteady, turn slightly back to the left so that the light remains steady.

Connection diagram

  1. One Way Connection
    EcoDim Smart LED dimmer Z-Wave User Manual  & troubleshooting 8
  2. Multiway master& slave wiring connection
    EcoDim Smart LED dimmer Z-Wave User Manual  & troubleshooting 9

Operation

SmartStart Inclusion
Smart Start-enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the Smart Start product will be added automatically within 10 minutes of being switched on in the network vicinity.

  1. Add the dimmer controller DSK into the primary controller SmartStart Provisioning List.
    (If your controller does not support SmartStart inclusion, please refer to the manual for your
    controller for non-SmartStart inclusion.).
  2. Power cycle once for the dimmer controller.
  3. The dimmer controller will send the “Explorer Auto inclusion” frame to start SmartStartInclusion.
  4. Wait a moment, the dimmer controller should be added to the controller.

Note: The dimmer controller will SmartStart Inclusion when it is removed from a Z-Wave network.
The Dimmer has a DSK string, you can key in the first five-digit to increment the SmartStart process, or you can scan a QR code. The QR code can be found on the  Dimmer controller or in the box.
Ex: 65286-19008-32952-20593- 44872-18102-41266-46651

Inclusion to a Z-Wave Network
Step 1.
Remove the device from the previous Z-Wave network if it has already been added to, otherwise pairing mode will fail.

EcoDim Smart LED dimmer Z-Wave User Manual  & troubleshooting 10

Remove from a Z-Wave Network
Method 1. From your Z-Wave hub interface, choose to delete or reset the device as instructed.
Method 2. Remove from the Device, see below instructions.

EcoDim Smart LED dimmer Z-Wave User Manual  & troubleshooting 11

Factory Reset

EcoDim Smart LED dimmer Z-Wave User Manual  & troubleshooting 12

Please Note:
This procedure should only be used when the primary controller is inoperable.
All configurations will be reset after the device is reset or removed from the network.

INDEX- Z-Wave Information

Technical Data

Z-Wave Frequency Z-Wave Frequency
Wireless Range up to 100m outside, on average up to 40m inside buildings
SDK 6.81.03
Explorer Frame Support Yes
Device Type Light Dimmer Switch
Generic Device Class GENERIC_TYPE_SWITCH_MULTILEVEL
Specific Device Class SPECIFIC_TYPE_POWER_SWITCH_MULTILEVEL
Role Type Always On Slave(AOS)
Routing Yes

Supported Command Class

The function of the Dimmer as a security and non-security device is identical. When a node includes in a S0 or S2 Z-Wave network, the node supports S0 or S2 unauthenticated class, S2 authenticated and so do the supported CCs.

Supported Command Classes Non-Secure Not Included Non-Secure Included Secure Secure
COMMAND_CLASS_ZWAVEPLUS_INFO_V2 Yes Yes
COMMAND_CLASS_TRANSPORT_SERVICE_V2 Yes Yes
COMMAND_CLASS_SECURITY_2_V1 Yes Yes
COMMAND_CLASS_SECURITY_V1 Yes Yes
COMMAND_CLASS_SUPERVISION_V1 Yes Yes
COMMAND_CLASS_VERSION_V2 Yes Yes
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 Yes Yes
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 Yes Yes
COMMAND_CLASS_ASSOCIATION_V2 Yes Yes
COMMAND_CLASS_POWERLEVEL_V1 Yes Yes
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 Yes Yes
COMMAND_CLASS_CONFIGURATION_V1 Yes Yes
COMMAND_CLASS_METER_V3 Yes Yes
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 Yes Yes
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 Yes Yes

Note for special commands

Z-Wave plus Info Command Report

Parameter Value
Z-Wave Plus Version V1
Role Type ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_ON
Node Type ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE
Installer Icon Type ICON_TYPE_GENERIC_LIGHT_DIMMER_SWITCH
User Icon Type ICON_TYPE_GENERIC_LIGHT_DIMMER_SWITCH

Association Group Info Command
Association is different from Inclusion. The Inclusion function of a device “includes” the device into a network, allowing it to communicate with other network devices. The association function “associates” two devices, enabling them to communicate directly without the need for a central controller.
a) Association Group Name Command Report

Association
Groups
Group
Name
Max
Nodes
Description
Group 1 Lifeline 5 The ASIC of Lifeline: 4C 69 66 65 6C 69 6E 65
1. When pressing and holding down the “Reset” button for 4S to reset the dimmer, send “Device Reset Locally Notification CC” to associated devices of  this group to report factory reset information.
2. When load state changes, send “Switch Multilevel Report CC” to associated devices of this group.
Group 2 Basic Set 5 Basic Set: 42 61 73 69 63 20 53 65 74
1. Short press the knob turn on the dimmer Sends Basic Set(0xFF) to associated devices 2. Short  press the knob  turn off the dimmer Sends Basic Set(0x00) to associated devices
Group 3 Switch
Multilevel
5 Switch Multilevel: 53 77 69 74 63 68 20 4D 75 6C 74 69 6C 65 76 65 6C
1. “Anti-Clockwise the knob” Sends Switch Multilevel Set(to decrease the brightness and keep  associated devices in sync with this device) to associated devices
2. “Clockwise the knob” Sends Switch Multilevel Set(to increase the brightness and keep associated devices in sync with this device) to associated devices
Group 4 External
Button
5 External Button: 45 78 74 65 72 6E 61 6C 20 42 75 74 74 6F 6E
1. External Button hold  send Switch Multilevel Start Level Change (Switchover dimmer Up/Down)
2. External Button release  send Switch Multilevel Stop Level Change

b) Association Group Info Command Report

Parameter Team No. Value
Profile Group 1 General: Lifeline, Profile MSB=0x00,Profile LSB=0x01
Profile Group 2 General: Lifeline, Profile MSB=0x20,Profile LSB=0x01
Profile Group 3 General: Lifeline, Profile MSB=0x20,Profile LSB=0x02
Profile Group 4 General: Lifeline, Profile MSB=0x20,Profile LSB=0x03

c) Set and unset associations
(Note: All association information will be cleared automatically once the dimmer is excluded from a network.)
The primary controller/Gateway send packets to the dimmer using “ Command Class ASSOCIATION”

d) Association Group Command List Command Report

Team No.

Command List Support

 

Group 1

COMMAND_CLASS_SWITCH_MULTI- SWITCH_MULTILEVEL_REPORT (0x03)
LEVEL (0x26)
COMMAND_CLASS_DEVICE_RE- DEVICE_RESET_LOCALLY_NOTIFICA-

TION(0x01)

SET_LOCALLY(0x5A)
Group 2 COMMAND_CLASS_BASIC(0x20) BASIC_SET(0x01)
Group 3 COMMAND_CLASS_SWITCH_MULTI- SWITCH_MULTILEVEL_SET(0x01)
LEVEL(0x26)
Group 4 COMMAND_CLASS_SWITCH_MULTI- SWITCH_MULTILEVEL_SET(0x01)
LEVEL(0x26)

Basic Command

Basic CC is maps to Multilevel CC
Basic Set = 255 maps to Multilevel Switch Set = 255
Basic Set = 0 maps to Multilevel Switch Set = 0
Basic Set = 1-99 maps to Multilevel Switch Set = 1-99
Basic Get/Report maps to Multilevel Switch Get/Report.

Configuration Command Parameters

The Dimmer offers a wide variety of advanced configuration settings. The below parameters can be accessed from the main controller’s configuration interface.

Parameter

Size Default Value

Description

1

1

00

State After Power Restored: The state the switch should return to once power is restored after power failure.
0 – Off.
1 – On.
2 – Returns to level before Power Outage

2

1

01

Notification when Load status change: The Dimmer will send a notification to the associated device (Group Lifeline) when the status of the Dimmer load is changed.
0 – The function is disabled.
1 – Send Switch Multilevel Report.

3

1

05

Default dimming speed, the unit is second. Valid value:0-100
0 – Instantly.
1 – Fast.
…100 – Slow.

5

1

0

Enable or Disable external switch to pair network.
0 – Disable.
1 – Enable.

6

1

0

Setting dimming way.
0 – Linear dimming.
1 – Logarithmic dimming.

7

1

0

Setting default brightness when turning on the dimmer from off status. The setting of 0 means that the dimmer will use parameter 1.
Valid value:0-99

8

1

0

Setting delay time when turning off, the unit is second. Valid value:0-60

You can find the full list of Z-wave commands on our website. www.ecodim.nl/downloads-smart-dimmer

EcoDim Smart LED dimmer Z-Wave User Manual  & troubleshooting 13WORKS WITH 
FIBAROEcoDim Smart LED dimmer Z-Wave User Manual  & troubleshooting 14www.ecodim.nl
EcoDim Smart LED dimmer Z-Wave User Manual  & troubleshooting 15EcoDim Smart LED dimmer Z-Wave User Manual  & troubleshooting 16EcoDim
Dr. Huber Noodtstraat 89
7001DV Doetinchem
[email protected]
+31 (0)314 844691

FAQ


Setting up EcoDim Smart LED dimmer Z-Wave User Manual is easy with these step-by-step instructions. Follow the steps are you are set-up in no time.

Using EcoDim Smart LED dimmer Z-Wave User Manual is simple by using this manual. Follow the instructions one by one and everything will be fine

Is EcoDim Smart LED dimmer Z-Wave User Manual stuck or not working properly? By resetting it you can set it back to the standard settings and everything should be back to normal. This works in many cases when problems arise.

This page contains the complete user instructions & manual for EcoDim Smart LED dimmer Z-Wave User Manual

All symbols, colors and codes for EcoDim Smart LED dimmer Z-Wave User Manual are explained in this instruction manual. You can find everything you need and moree