EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual

EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual & troubleshooting

EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual  & troubleshooting 1

Copeland ™ Outdoor
Refrigeration Unit, X-Line Series
Fixed speed and digital capacity units for medium and low-temperature applications

EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual  & troubleshooting 2Small-Format Stores • Convenience Stores • Foodservice Establishments
R-22, 134a, 404A/507A, 407C/A, 448A/449A • ¾ – 6 HP

EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual  & troubleshooting 3

Innovative design based on three factors demanded by industry users.

1. Energy Efficiency
Copeland Outdoor Refrigeration Units signifi cantly reduce energy consumption by utilizing scroll and digital scroll compressor technology, variable speed fan motors, large capacity condenser coils and advanced control algorithms. Compared to hermetic reciprocating units, end-users will save up to 50% in energy costs.

EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual  & troubleshooting 4

2.Reliability
Combining the proven reliability of Copeland scroll compressors with advanced onboard diagnostics, equipment reliability is greatly enhanced. Fault code alerts and fault code retrieval capabilities provide information to help improve speed and accuracy of system diagnostics. Integrated electronics provide protection against overcurrent, over-heating, incorrect phase rotation, compressor cycling, high-pressure resets, low-pressure cut-outs, and liquid flood-back conditions that cause unexpected performance losses or worse, unplanned equipment failure. As part of the Emerson family f products, Copeland Outdoor  Refrigeration Units provide unsurpassed access to system status, diagnostics, and operational control.

3.Flexibility
The lightweight and slim-line profile ease the installation process. The ultra-quiet variable-speed fan motor significantly reduces exterior sound levels, allowing use in noise-restricted residential zones. With high and low ambient operation capability, coated coils for coastal applications, multi-refrigerant capabilities, and optional all mounting capability, the units deliver unmatched mounting and environmental location flexibility. Copeland outdoor Refrigeration Units are perfectly suited for walk-in and display case applications. All units integrate any benefits of scroll compressor technology, fan speed control, and advanced onboard diagnostics, delivering higher energy efficiency and lower sound levels while ensuring reliable performance and operation in foodservice applications.

EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual  & troubleshooting 5

Two sound values shown represent the X-Line unit’s lowest and highest operating dBA measurements, or typical industry outdoor unit published data, for both  MT and LT products. Sound pressure values are 10 feet from the unit at 25°F evap for MT and -10°F evap for LT at 90°F ambient. A sound reduction of up to 3 dBA ill occur in ambient temperatures below 70°F This data is typical of ‘free field’ conditions for horizontal air-cooled condensing units and may vary depending on the condensing unit installation. There are many factors that affect the sound reading of a condensing unit such as unit mounting, reflecting walls, background noise and operating condition.

Standard Features

  •  Electronic control module consolidating all unit operations, defrost, diagnostics, compressor protection, and  communications
  • External service valves and hinged service panel for easy setup and service
  • Standard moisture indicator and liquid filter drier
  • Quiet variable speed condenser fan
  •  Heated and insulated receiver with pressure relief valve
  • Powder-coated galv-annealed chassis and coated condenser fins for corrosion protection
  • Standard accumulator and oil separator on low temp models.
    Optional accumulator on only fixed speed medium temp models.

EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual  & troubleshooting 6

Accessories

Part Number Description Purpose
074-7286-00 Wall bracket Allows mounting unit to walls
074-7289-00 Adjustable stand Raises unit 12 inches from ground level
943-0224-00 PC interface kit Allows direct connection of unit to PC
943-0058-00 Remote display Control/view unit status up to 30 feet from unit

Nomenclature

X Family = X-Line
F F = Multi-refrigerant
A A = Air-Cooled
M L = Low Temp

M = Medium Temp

P = Multiple Applications

0 75 to 6.0 = HP
2
0
Z Z = Scroll

D = Digital Scroll

T CFV = 208/230V-1ph60Hz

TFC = 208/230V-3ph60Hz

F
C
0 0 = UL Listed Product
8 81 = Standard
1

To place an order select Base Model > Electrical > Bill of Material

Feature
Energy improvement
Sound improvement
Diagnostic protection capabilities Slim profi le, lighter weight, and optional wall mount capability
Multi-refrigerant*
Emerson family of electronics

* Visit Climate.Emerson.com/OPI for specifi c refrigerant approvals for each model.

Owner/Enterprise Benefit

  • Lower operating costs
  • Creating a more comfortable environment for guests
  • Benefi cial for regions with noise ordinances
  • Reduce nuisance calls
  • Extends life of your equipment
  • Faster, more accurate service, and reduced call-backs
  • Maintains your equipment to original standards, maintaining energy effi ciency and temperature control
  • Have confi dence in what your contractor is fi xing
  • Lower installation costs
  • Improved appearance of your enterprise site
  • Avoids more costly solutions for potential location issues
  •  R-22, R-134a, R-404A, R-407C/A, R-448/449A
  •  Scalable electronics can operate as a stand-alone unit or connect as part of a full intelligent store.

Copeland Digital Outdoor Refrigeration Unit, X-Line Series The compact solution for continuous capacity modulation

The Copeland Digital Outdoor Refrigeration Unit sets a new standard for energy effi ciency, reliability, and installation fl exibility. With 20-100% modulation now  available and expanded refrigerant approvals, its  industry leading on-board diagnostics and system protection can help optimize operational effi ciency and  deliver peace of mind to any end user. Digital X-Line units are available for applications commonly found in  today’s food service and food retail establishments.

The perfect solution for refrigeration applications with wide load variation:

  •  Walk-In Coolers
  • Food Preparation Rooms
  •  Display Cases
  • Industrial Process Chillers

Digital compression technology means fewer condensing units are needed to install and maintain for numerous refrigeration loads, which results in fewer line runs, lower refrigerant charges, and faster installation.

EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual  & troubleshooting 7

A Superior Solution for Food Safety
Digital modulation enables tighter control of case temperatures. This provides supermarkets and foodservice establishments with the security of knowing that their food is safe from harmful bacteria growth and other harmful micro-organisms.

A Superior Solution for Energy Savings
Traditional modulation technologies consume close to full load energy no matter what the required capacity. Copeland digital scroll compressor technology reduces power consumption linearly as it modulates capacity resulting in optimum system performance and control, as shown in Chart A.

Chart A
Temperature control comparison digital vs. standard technology.EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual  & troubleshooting 8

What’s Inside

EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual  & troubleshooting 9

Dimensional Drawings

EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual  & troubleshooting 10EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual  & troubleshooting 11

Application Engineering Bulletins

available at Climate.Emerson.com/OPI 
4-1273 Factors to Consider in Converting Compressor
Rated Capacity to Actual Capacity
4-1327 Economized Vapor Injection (EVI) Compressors
11-1147 Suction Accumulators
11-1297 Liquid Line Filter Driers
17-1260 Compressor Overheating
17-1268 Compressor Ratio as it Affects Compressor Reliability
22-1182 Liquid Refrigerant Control in Refrigeration  and Air Conditioning Systems
5-1412 Copeland Scroll Outdoor Refrigeration Unit – X-Line User Manual (This bulletin is provided with
each unit and is a source for additional product details.

For more information visit Climate.Emerson.com/CopelandOutdoorUnit

Diagnostic Features

On-board diagnostics provide connectivity to facility management control systems (including Emerson’s Site  Supervisor suite of control products) to alert owner/operators of faults and key performance indicators (KPIs).

  • Over-current protection
  • Incorrect phase detection
  • High-pressure lockout
  •  Flood-back prediction
  •  Demand Cooling™
  •  Flooded start protection (“bump-start” logic)
  • Discharge temperature protection
  • Anti-short cycle time delay
  • Digital fault code display/remote alarming
  • Over/under voltage protection

EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual  & troubleshooting 12

Specifications

Unit Model Compressor Electrical Chassis Size L W H Refrigerant Connections Receiver Capacity (Lbs @ 90% Volume)  

MCA

Max Over- current Protection*
Liquid Suction R-134a R-22 R-404A R-407A R-407C R-448A R-449A
XFAL-008Z-CFV ZF03KAE-PFV  

 

 

 

 

1 FAN

16.7 40.5 33.1  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2 S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7/8 S

 

 

 

 

 

 

 

 

N/A

 

 

 

 

 

 

 

 

N/A

 

 

 

 

 

9.1

 

 

 

 

 

10

 

 

 

 

 

10

 

 

 

 

 

9.7

 

 

 

 

 

9.7

9.1 15
XFAL-008Z-TFC ZF03KAE-TF5 16.7 40.5 33.1 6.2 15
XFAL-009Z-CFV ZF04KAE-PFV 16.7 40.5 33.1 10.3 15
XFAL-009Z-TFC ZF04KAE-TF5 16.7 40.5 33.1 9.3 15
XFAL-010Z-CFV ZF05KAE-PFV 16.7 40.5 33.1 11.9 15
XFAL-010Z-TFC ZF05KAE-TF5 16.7 40.5 33.1 10.4 15
XFAL-012Z-CFV ZF07KAE-PFV 16.7 40.5 33.1 18.4 30
XFAL-012Z-TFC ZF07KAE-TF5 16.7 40.5 33.1 11.8 15
XFAL-020Z-CFV ZXI06KCE-PFV 16.7 40.5 33.1 21.55 35
XFAL-020Z-TFC ZXI06KCE-TF5 16.7 40.5 33.1 16.18 25
XFAL-030Z-TFC ZXI09KCE-TF5 16.7 40.5 33.1 17.18 25
XFAL-035Z-CFV ZXI11KCE-PFV 16.7 40.5 33.1 34.05 50
XFAL-040Z-CFV ZXI14KCE-PFV  

 

2 FAN

16.7 40.5 48.9  

 

13.4

 

 

14.8

 

 

14.7

 

 

14.2

 

 

14.3

40.1 60
XFAL-040Z-TFC ZXI14KCE-TF5 16.7 40.5 48.9 27.1 45
XFAL-050Z-TFC ZXI15KCE-TF5 16.7 40.5 48.9 28.85 45
XFAL-051Z-CFV ZXI16KCE-PFV 16.7 40.5 48.9 44.73 70
XFAL-060Z-TFC ZXI18KCE-TF5 16.7 40.5 48.9 33.98 50
XFAM-008Z-CFV ZB06KAE-PFV  

 

 

 

 

 

 

 

 

 

 

1 FAN

16.7 40.5 33.1  

 

 

 

 

 

 

 

 

 

 

10.7

 

 

 

 

 

 

 

 

 

 

 

10.5

 

 

 

 

 

 

 

 

 

 

 

9.1

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

9.7

 

 

 

 

 

 

 

 

 

 

 

9.7

9.3 15
XFAM-008Z-TFC ZB06KAE-TF5 16.7 40.5 33.1 8.05 15
XFAM-010Z-CFV ZB07KAE-PFV 16.7 40.5 33.1 9.3 15
XFAM-010Z-TFC ZB07KAE-TF5 16.7 40.5 33.1 8.1 15
XFAM-012Z-CFV ZB08KAE-PFV 16.7 40.5 33.1 11.1 15
XFAM-012Z-TFC ZB08KAE-TF5 16.7 40.5 33.1 8.1 15
XFAM-015Z-CFV ZS09KAE-PFV 16.7 40.5 33.1 13.55 20
XFAM-015Z-TFC ZS09KAE-TF5 16.7 40.5 33.1 11.05 15
XFAM-017Z-CFV ZS11KAE-PFV 16.7 40.5 33.1 16.8 25
XFAM-017Z-TFC ZS11KAE-TF5 16.7 40.5 33.1 14.05 20
XFAM-020Z-CFV ZS13KAE-PFV 16.7 40.5 33.1 16.1 25
XFAM-020Z-TFC ZS13KAE-TF5 16.7 40.5 33.1 13.2 20
XFAM-022Z-CFV ZS15KAE-PFV 16.7 40.5 33.1 20.68 35
XFAM-022Z-TFC ZS15KAE-TF5 16.7 40.5 33.1 14.3 20
XFAM-025Z-CFV ZS19KAE-PFV 16.7 40.5 33.1 23.6 40
XFAM-025Z-TFC ZS19KAE-TF5 16.7 40.5 33.1 18.2 30
XFAM-030Z-CFV ZS21KAE-PFV 16.7 40.5 33.1 30.05 50
XFAM-030Z-TFC ZS21KAE-TF5 16.7 40.5 33.1 20.05 30
XFAM-030D-CFV ZBD21KCE-PFV 16.7 40.5 33.1 24.7 40
XFAM-030D-TFC ZBD21KCE-TF5 16.7 40.5 33.1 16.8 25
XFAM-033Z-CFV ZS26KAE-PFV 16.7 40.5 33.1 30.6 50
XFAM-033Z-TFC ZS26KAE-TF5 16.7 40.5 33.1 20.4 30
XFAM-037Z-CFV ZS29KAE-PFV 16.7 40.5 33.1 33.7 50
XFAM-037Z-TFC ZS29KAE-TF5 16.7 40.5 33.1 26.7 45
XFAM-040D-TFC ZBD30KCE-TF5  

 

 

 

2 FAN

16.7 40.5 33.1 21.7 35
XFAM-045Z-CFV ZS33KAE-PFV 16.7 40.5 48.9  

 

 

15.7

 

 

 

15.5

 

 

 

13.4

 

 

 

14.8

 

 

 

14.7

 

 

 

14.2

 

 

 

14.3

37.35 60
XFAM-045Z-TFC ZS33KAE-TF5 16.7 40.5 48.9 29.98 50
XFAM-050Z-CFV ZS38K4E-PFV 16.7 40.5 48.9 41.85 70
XFAM-050Z-TFC ZS38K4E-TF5 16.7 40.5 48.9 28.85 45
XFAM-050D-CFV ZBD38KCE-PFV 16.7 40.5 48.9 45.0 70
XFAM-050D-TFC ZBD38KCE-TF5 16.7 40.5 48.9 31.7 50
XFAM-060Z-TFC ZS45K4E-TF5 16.7 40.5 48.9 31.98 50
XFAM-060D-TFC ZBD45KCE-TF5 16.7 40.5 48.9 30.2 50
XFAP-015Z-CFV ZS09KAE-PFV  

 

 

 

 

 

 

1 FAN

16.7 40.5 33.1  

 

 

 

 

 

 

10.7

 

 

 

 

 

 

 

10.5

 

 

 

 

 

 

 

9.1

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

9.7

 

 

 

 

 

 

 

9.7

13.55 20
XFAP-015Z-TFC ZS09KAE-TF5 16.7 40.5 33.1 11.05 15
XFAP-017Z-CFV ZS11KAE-PFV 16.7 40.5 33.1 16.8 25
XFAP-017Z-TFC ZS11KAE-TF5 16.7 40.5 33.1 14.05 20
XFAP-020Z-CFV ZS13KAE-PFV 16.7 40.5 33.1 16.1 25
XFAP-020Z-TFC ZS13KAE-TF5 16.7 40.5 33.1 13.2 20
XFAP-022Z-CFV ZS15KAE-PFV 16.7 40.5 33.1 20.68 35
XFAP-022Z-TFC ZS15KAE-TF5 16.7 40.5 33.1 14.3 20
XFAP-025Z-CFV ZS19KAE-PFV 16.7 40.5 33.1 23.6 40
XFAP-025Z-TFC ZS19KAE-TF5 16.7 40.5 33.1 18.2 30
XFAP-030Z-CFV ZS21KAE-PFV 16.7 40.5 33.1 30.05 50
XFAP-030Z-TFC ZS21KAE-TF5 16.7 40.5 33.1 20.05 30
XFAP-033Z-CFV ZS26KAE-PFV 16.7 40.5 33.1 30.6 50
XFAP-033Z-TFC ZS26KAE-TF5 16.7 40.5 33.1 20.4 30
XFAP-037Z-CFV ZS29KAE-PFV 16.7 40.5 33.1 33.7 50
XFAP-037Z-TFC ZS29KAE-TF5 16.7 40.5 33.1 26.7 45
XFAP-045Z-CFV ZS33KAE-PFV  

 

2 FAN

16.7 40.5 48.9  

 

15.7

 

 

15.5

 

 

13.4

 

 

14.8

 

 

14.7

 

 

14.2

 

 

14.3

37.35 60
XFAP-045Z-TFC ZS33KAE-TF5 16.7 40.5 48.9 29.98 50
XFAP-050Z-CFV ZS38K4E-PFV 16.7 40.5 48.9 41.85 70
XFAP-050Z-TFC ZS38K4E-TF5 16.7 40.5 48.9 28.85 45
XFAP-060Z-TFC ZS45K4E-TF5 16.7 40.5 48.9 31.98 50

Max Over-current rating applies to the condensing unit only. Additional evaporator fan or defrost heater loads must be considered. See evaporator manufacturer literature for additional load requirements.
† Defrost relay for single phase heaters only. For three-phase heaters, additional contactors are required.]

Capacity and Effi ciency

Medium Temp Capacity @ 95°F Ambient/25°F Evap, 65° RG; 5° subcooling
Model Number*  

Comp.

R-134a R-22 R-404A R-407A R-407C R-448A              R-449A
Cap. AWEF Cap. AWEF Cap. AWEF Cap. AWEF Cap. AWEF Cap. AWEF Cap. AWEF
XFAM-008Z-CFV ZB06KAE 4,830 8,030 7.6 7,220 7.6 6,770 7,390 7.6 7,400 7.6
XFAM-008Z-TFC ZB06KAE 4,830 8,030 7.6 7,220 7.6 6,770 7,390 7.6 7,400 7.6
XFAM-010Z-CFV ZB07KAE 5,870 9,690 7.6 8,780 7.6 8,080 8,780 7.6 8,790 7.6
XFAM-010Z-TFC ZB07KAE 5,870 9,690 7.6 8,780 7.6 8,080 8,780 7.6 8,790 7.6
XFAM-012Z-CFV ZB08KAE 6,880 11,000 7.6 10,200 7.6 9,370 10,300 7.6 10,300 7.6
XFAM-012Z-TFC ZB08KAE 6,880 11,000 7.6 10,200 7.6 9,370 10,300 7.6 10,300 7.6
XFAM-015Z-CFV ZS09KAE 7,810 12,400 12,400 7.6 11,400 7.6 10,900 10,700 7.6 10,700 7.6
XFAM-015Z-TFC ZS09KAE 7,810 12,400 12,400 7.6 11,400 7.6 10,900 10,700 7.6 10,700 7.6
XFAM-017Z-CFV ZS11KAE 9,270 14,100 14,400 7.6 13,500 7.6 12,900 12,800 7.6 12,800 7.6
XFAM-017Z-TFC ZS11KAE 9,270 14,100 14,400 7.6 13,500 7.6 12,900 12,800 7.6 12,800 7.6
XFAM-020Z-CFV ZS13KAE 10,500 16,000 17,000 7.6 15,300 7.6 14,600 14,500 7.6 14,500 7.6
XFAM-020Z-TFC ZS13KAE 10,500 16,000 17,300 7.6 15,300 7.6 14,600 14,600 7.6 14,600 7.6
XFAM-022Z-CFV ZS15KAE 12,600 18,700 20,300 7.6 18,300 7.6 17,500 17,300 7.6 17,300 7.6
XFAM-022Z-TFC ZS15KAE 12,600 18,700 20,300 7.6 18,300 7.6 17,500 17,400 7.6 17,300 7.6
XFAM-025Z-CFV ZS19KAE 14,100 21,000 21,700 7.6 20,400 7.6 19,600 19,200 7.6 19,200 7.6
XFAM-025Z-TFC ZS19KAE 14,300 21,000 21,600 7.6 20,400 7.6 19,600 19,200 7.6 19,200 7.6
XFAM-030Z-CFV ZS21KAE 18,700 27,600 28,200 7.6 26,300 7.6 25,800 26,500 7.6 26,500 7.6
XFAM-030Z-TFC ZS21KAE 18,700 27,600 28,200 7.6 26,300 7.6 25,800 26,500 7.6 26,500 7.6
XFAM-033Z-CFV ZS26KAE 20,600 30,300 31,700 7.6 29,300 7.6 28,400 28,100 7.6 28,100 7.6
XFAM-033Z-TFC ZS26KAE 20,600 30,300 30,700 7.6 29,100 7.6 28,400 28,700 7.6 28,700 7.6
XFAM-037Z-CFV ZS29KAE 22,800 33,500 35,300 7.6 31,800 7.6 31,400 32,500 7.6 32,500 7.6
XFAM-037Z-TFC ZS29KAE 22,800 33,500 34,200 7.6 31,800 7.6 31,400 33,300 7.6 33,300 7.6
XFAM-045Z-CFV ZS33KAE 25,600 37,900 39,100 7.6 36,800 7.6 35,400 36,800 7.6 36,800 7.6
XFAM-045Z-TFC ZS33KAE 25,600 37,900 39,100 7.6 36,800 7.6 35,400 36,800 7.6 36,800 7.6
XFAM-050Z-CFV ZS38K4E 30,300 43,000 46,700 7.6 43,600 7.6 42,900 44,500 7.6 44,500 7.6
XFAM-050Z-TFC ZS38K4E 29,400 43,000 46,700 7.6 43,600 7.6 42,900 44,500 7.6 44,500 7.6
XFAM-060Z-TFC ZS45K4E 35,000 51,500 53,000 7.6 51,500 7.6 51,000 52,500 7.6 52,500 7.6
Digital
XFAM-030D-CFV ZBD21KCE 27,000 7.6 24,000 7.6 23,200 24,600 7.6 24,600 7.6
XFAM-030D-TFC ZBD21KCE 27,000 7.6 24,000 7.6 23,200 24,600 7.6 24,600 7.6
XFAM-040D-TFC ZBD30KCE 36,900 7.6 35,400 7.6 32,200 34,000 7.6 34,000 7.6
XFAM-050D-CFV ZBD38KCE 45,300 7.6 44,400 7.6 40,100 42,500 7.6 42,500 7.6
XFAM-050D-TFC ZBD38KCE 45,300 7.6 44,400 7.6 40,100 42,500 7.6 42,500 7.6
XFAM-060D-TFC ZBD45KCE 52,000 7.6 49,100 7.6 46,700 49,400 7.6 49,400 7.6

*Data for XFAM models also applies to equivalent XFAP models.
This refrigeration system is designed and certifi ed for use in walk-in cooler applications. See Emerson.com/OPI for complete specifi cations.

Low Temp Capacity @ 95°F Ambient/-10°F Evap
Model Number*  

Compressor

R-404A R-407A R-407C R-448A / 449A 507A
Cap. AWEF Cap. AWEF Cap. AWEF Cap. AWEF Cap. AWEF
XFAL-008Z-CFV ZF03KAE 4230 2.92 3590 2.89 3360 3740 2.9 4230
XFAL-008Z-TFC ZF03KAE 4230 2.92 3580 2.89 3360 3740 2.9 4230
XFAL-009Z-CFV ZF04KAE 5770 2.98 4890 2.94 4540 5080 2.95 5770
XFAL-009Z-TFC ZF04KAE 5770 2.98 4890 2.94 4540 5080 2.95 5770
XFAL-010Z-CFV ZF05KAE 6960 3.04 5780 2.98 5390 6020 2.99 6960
XFAL-010Z-TFC ZF05KAE 6960 3.04 5780 2.98 5390 6020 2.99 6960
XFAL-012Z-CFV ZF07KAE 10700 3.15 9020 3.13 8210 9070 3.14 10700
XFAL-012Z-TFC ZF07KAE 10700 3.15 9020 3.13 8210 9070 3.14 10700
XFAL-020Z-CFV ZXI06KCE 12910 3.15 9230 3.15 9110 11290 3.15 12910
XFAL-020Z-TFC ZXI06KCE 12910 3.15 9230 3.15 9110 11290 3.15 12910
XFAL-030Z-TFC ZXI09KCE 16800 3.15 13450 3.15 11050 13930 3.15 16800
XFAL-035Z-CFV ZXI11KCE 18900 3.15 15120 3.15 14560 17200 3.15 18900
XFAL-035Z-TFC ZXI11KCE 18900 3.15 15120 3.15 14560 17200 3.15 18900
XFAL-040Z-CFV ZXI14KCE 24210 3.15 21080 3.15 19760 22870 3.15 24210
XFAL-040Z-TFC ZXI14KCE 24210 3.15 21080 3.15 19760 22870 3.15 24210
XFAL-050Z-TFC ZXI15KCE 26620 3.15 22170 3.15 20530 25660 3.15 26620
XFAL-051Z-CFV ZXI16KCE 26620 3.15 22170 3.15 20530 25660 3.15 26620
XFAL-060Z-TFC ZXI18KCE 33720 3.15 29270 3.15 25380 27680 3.15 33720

*Data for units containing ZF compressors are rated at 40-degree return gas; ZI compressors are rated at 65-degree return gas
This refrigeration system is designed and certified for use in walk-in freezer applications. See Emerson.com/OPI for complete specifications.

Condensing unit performance, electrical, and mechanical information can be accessed online at Climate.Emerson.com/OPI via Online Product Information (OPI).

About Emerson

Emerson (NYSE: EMR), headquartered in St. Louis, Missouri (USA), is a global technology and engineering company providing innovative solutions for customers in industrial, commercial, and residential markets. Our Emerson Automation Solutions business helps process, hybrid, and discrete manufacturers maximize production, protect personnel and the environment while optimizing their energy and operating costs. Our Emerson Commercial and Residential Solutions business helps ensure human comfort and health, protect food quality and safety, advance energy efficiency, and create sustainable infrastructure. For more information visit Emerson.com.Climate.

Emerson.com/CopelandOutdoorUnit
2009IP-50 R10 (7/20) Emerson and Copeland are trademarks of Emerson Electric Co. or one of its affiliated companies. ©2020 Emerson Climate Technoligies, Inc. All rights reserved.

EMERSON.CONSIDER IT SOLVED.

References

FAQ


Setting up EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual is easy with these step-by-step instructions. Follow the steps are you are set-up in no time.

Using EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual is simple by using this manual. Follow the instructions one by one and everything will be fine

Is EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual stuck or not working properly? By resetting it you can set it back to the standard settings and everything should be back to normal. This works in many cases when problems arise.

This page contains the complete user instructions & manual for EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual

All symbols, colors and codes for EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual are explained in this instruction manual. You can find everything you need and moree