GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual

GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual & troubleshooting

GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 1

GLOBAL INDUSTRIAL 412597 Digital Crane Scale With RemoteGLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 2

Instruction

Technical parameter

  • Accuracy class                                       II
  • Tare range                                            100% max. capacity
  • Initial zero range                                  +10% max. capacity
  • Manually zero range                            +2% max. capacity
  • Operation temperature& humidity      14-104°F: s90%Relative Humidity (RH)
  • Storage temperature                            40-158°F

Battery instructions

The crane scale uses a 6v/4.5Ah rechargeable battery and lasts for about 80-150 hours. The battery charging port and battery indicator are on the back of the crane scale. The scale fully charges within 8-12 hours. The battery indicator turns from yellow to green when fully charged.

Referenced dimensionsGLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 3

Model No.  

Product Description

Maximum

Capacity (lbs.)

Division (lbs./kgs) Size LxWxH (inches) Weight
 

 

412604

LED Digital Crane Scale With Remote

500lb x 0.2lb

 

550

 

0.2/0.

 

8.5”x 5.75”x15.16”

 

10.14

 

 

412597

LED Digital Crane Scale With Remote

1,000 lb x 0.2 lb

 

1100

 

0.2/0.1

 

8.5”x 5.75”x15.16”

 

10.14

 

 

412598

LED Digital Crane

Scale With Remote 3,000lb x 1lb

 

3300

 

1/

 

8.5”x 5.75”x17.13”

 

15.43

 

 

412605

LCD Digital Crane

Scale with Remote, 3,000 lb x 1 lb

 

3300

 

1/

 

8.5”x 5.75”x17.13”

 

15.43

Operation InstructionsGLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 4

  • Power on
    Press the power button GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 5for 1 second.
  • Power off
    Press the power buttonGLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 6. The scale will turn off automatically if not used for 30 minutes.
  • Zero
    Press the zero button GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 7to zero the scale.
  • Tare
    Press the tare button GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 8to enter the net weight mode. The new net weight will display as zero. Press the tare button GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 9again to return to the gross weight mod and display the gross weight.
  • Hold
    Press the hold button GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 10to keep the current weight on the display. Press the hold button GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 11again to stop holding the weight on the display. If an object is blocking the display while it is weighed, this function can help you view the object’s weight after it’s removed.

Advanced operation

2nd Mode

Some buttons have a 2nd function. Press the 2nd button GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 12then press a different button to use its 2nd function. [2nd] will be displayed on the screen when the 2nd button is activated. Press the power button GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 13to exit.

Accumulation function

Load a weight on the scale until it is stable. Press the accumulation button GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 14to add the current weight to an accumulative total. The display will read [ ACC ]. If the max weight has been reached, no more weight measurements can be added and the display will read [noACC]. Press the delete button GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 15to remove the last added weight from the accumulated total. The display will read [DEL] when the last weight was removed If there is no weight to remove, the display will read [noDEL]. Press GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 16to see the number of weights added to the accumulated total displayed as [n*** ]. Then the total accumulated weight will be shown for 3 seconds before returning to the weighing screen. Press the [2nd] GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 17button then the delete button GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 18to clear all the accumulation data. The display will read [CLEAR] to confirm all the weights were deleted.

Weight display

Press GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 19to save the current weight value. [STORE] will be displayed when the weight is saved. Press to see the last weird saved, [LAST0]. Press or to look through the other saved weights. The most recent weight saves as 0 and the first weight saved as 9. Press GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 20to display the corresponding weight for 2 seconds. The display will return back to weighing mode.

Switching between lbs./kg

Press the [2nd] button GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 21then press GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 22to covert the weight unit between lbs. and kg.

Preset tare weight

Press the [2nd] button GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 23then pressGLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 24. The display will read [00000]. Use these keys GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 25GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 26GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 27GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 28to input a tare weight value. Then press GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 29to confirm the input value. The crane scale will enter the net weight mode.

Parameter setting

Press the [2nd] button GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 30then press GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 31to adjust the following settings: adjust division, delay automatic off, delay idle, filter intensity, display brightness, zero range, stable intensity, hold mode, warning tone, kg/lb conversion. After each operation, press GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 32to confirm. Press GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual  & troubleshooting 33to exit.

Content Display Parameter instruction Default value
Display division E 0.02 = 0.02kg/lb

0.05 = 0.05kg/lb

0.1 = 0.1kg/lb

0.2 = 0.2kg/lb

0.5 = 0.5kg/lb

1    = 1kg/lb

2    = 2kg/lb

1
Automatic power off OFF 00 = close this function 10 = 10 minutes delay

30 = 30 minutes delay

60 = 60 minutes delay

90 = 90 minutes delay

10
Idle mode 1] IDL 00 = close this function 10 = 10 minutes delay

30 = 30 minutes delay

60 = 60 minutes delay

90 = 90 minutes delay

30
Kg/lb

conversion

UNS 0 = kg/lb conversion off

1= kg/lb conversion on

1
Content Display Parameter instruction Default value
Hold mode HOLD 0 =close hold function 1 =Peak hold

2 =Data Hold

3 =Auto Hold

4 =Animal scale function

2
Zero range ZERO 0=close manually zero setting and Initial zero range

1=Initial zero range±10% manually zero range±2%

2= Initial zero range 100%

manually zero range 100%

1
Filter intensity FIL 0=close the function 1=weak

2=moderate

3=strong

2
Stable intensity STB 0=weak 1=moderate

2=strong

1
Warning tone BEEP 0  close warning tone

1  open warning tone

1
Display brightness LEDb 1=light

2= moderate 3=dark

1
Zero track speed ZTS 0= no zero tracking 1=±0.5d/s

2=±1d/s

3=±2d/s

4=±5d/s

1

Battery power level checking

Press the [2nd] button then press to see the battery power level displayed in this format [U 6.**]. The display returns to weighing mode after 2 seconds.

Internal code checking

Press the [2nd] button then press to display the internal code for Maintenance and debugging. Press the [2nd] button then press to return to the weighing mode.

Display Codes Explanations
U 6.28 Battery power remaining.
oFF Power off.
ACC Weight added to accumulated total.
noACC No more weights can be added to the accumulated total.
dEL Clear the last accumulation value data.
nodEL Cannot be cleared.
CLEAr Clear all the accumulation data.
StorE Save the display value data.
LASt0 See the last weight added to the accumulated total

Troubleshooting Display Codes

Display Codes Cause Solution
Err6 Exceed zero range. Ensure the crane is not moving and press

the zero button.

uuuuuu Overload. Reduce the weight.
nnnnnn Weight measured is lower than

the minimum value or the scale is moving.

Ensure the scale is not moving.
2nd 2nd button pressed. First press the 2nd button then press another button to use its 2nd function. Press the power button to cancel.

Press the 2nd button twice to enter the

calibration mode.

FAQ


Setting up GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual is easy with these step-by-step instructions. Follow the steps are you are set-up in no time.

Using GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual is simple by using this manual. Follow the instructions one by one and everything will be fine

Is GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual stuck or not working properly? By resetting it you can set it back to the standard settings and everything should be back to normal. This works in many cases when problems arise.

This page contains the complete user instructions & manual for GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual

All symbols, colors and codes for GLOBAL INDUSTRIAL 412597 Digital Crane Scale With Remote User Manual are explained in this instruction manual. You can find everything you need and moree