  • 120VAC OR 24VAC
  •  On/Off OR Hi/Low

MATERIAL: 304 STAINLESS STEEL
Hi/Lo MODELS HAVE A 40% REDUCTION IN BTU ON LOW SETTING

PART NUMBERS STND
BTU
DIMENSION CHART
A” B” C”
24X12SSEI-H 75K 24 12 56LX28W
30X1255E1-H 100K 30 12 56LX28W
36X14S5E1-H 125K 36 14 64LX32W
42X1455E1-H 150K 42 14 64LX32W
54X16S5E1-H 200K 54 16 76LX38W
66X16SSEI-H 250K 66 16 88LX38W
78X1655E1-H 300K 78 16 90LX38W
90X1655E1-H 350K 90 16 112LX38W

Notes:

  1. PROPER VENTING
    ● ENCLOSURES: Recommend 4 each 18 sq. in. vents on opposing sides (Minimum 2 each 18 sq. in. vents).
    ● BOWLS (Copper, concrete, or metal) – Bowl to be raised above the mounting surface minimum of 3/4″ gap; Bowl to have a minimum of 6″ diameter hole in the bottom.

 GAS SUPPLY – FOR USE WITH FIXED PIPING SYSTEMS ONLY – NOT FOR USE WITH SMALL TANKS.
● Natural Gas: Operating Supply Pressure: Minimum: 6.0″ W.C.; Maximum: 7.0″ W.C.
● LP Gas: Operating Supply Pressure: Minimum: 10.0″ W.C.; Maximum: 11.0″ W.C.
IMPORTANT: Ensure any flex line that may be used from the permanent main fuel supply to the product is rated to the stated max BTU of the product and certified to ANSI Z21.75*CSA 6.27.
1. MODIFICATION OF THE PRODUCT WILL VOID ANY CERTIFICATION AND WARRANTY.
2. FOLLOW ALL MANUFACTURER INSTALLATION INSTRUCTIONS AND LOCAL CODES.
3. ALL DIMENSIONS ARE CONSIDERED TRUE AND REFLECT THE MANUFACTURER’S SPECIFICATIONS AS OF THE REVISION DATE.
4. DO NOT SCALE DRAWING.
5. THESE DRAWINGS ARE FOR SIZING AND PLANNING PURPOSES. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE
TIME OF DEVELOPMENT. THE MANUFACTURER’S RESPONSIBLE FOR THE ACCURACY OF THE DRAWING.
6. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info
REFERENCE NUMBER 771-044.
ELECTRONIC IGNITION
EI RECTANGLE – H BURNER – FLAME SENSING WITH ELECTRONIC HOT SURFACE IGNITION

HEARTH PRODUCTS CONTROLS
3050 PLAINFIELD RD.
KETTERING, OH 45432
TOLL-FREE: 1-877-433-7001
PHONE: (937) 433-7000
FAX: (937) 433-0704
www.hpcfire.com

References

FAQ


Setting up HPC CSA CERTIFIED-OUTDOOR User Guide is easy with these step-by-step instructions. Follow the steps are you are set-up in no time.

Using HPC CSA CERTIFIED-OUTDOOR User Guide is simple by using this manual. Follow the instructions one by one and everything will be fine

Is HPC CSA CERTIFIED-OUTDOOR User Guide stuck or not working properly? By resetting it you can set it back to the standard settings and everything should be back to normal. This works in many cases when problems arise.

This page contains the complete user instructions & manual for HPC CSA CERTIFIED-OUTDOOR User Guide

All symbols, colors and codes for HPC CSA CERTIFIED-OUTDOOR User Guide are explained in this instruction manual. You can find everything you need and moree