RENOGY 97Wh Power Bank User Manual

RENOGY 97Wh Power Bank User Manual & troubleshooting

RENOGY 97Wh Power Bank User Manual  & troubleshooting 1

RENOGY 97Wh Power Bank

RENOGY 97Wh Power Bank User Manual  & troubleshooting 2

SPECIFICATION

 

Battery

18650 Lithium-ion battery Nominal Voltage: 14.52V

Rated Capacity: 6700mAh,  97.28Wh

Input  (AC Adaptor) 18V/ 2A
Input  (Car Charger) 11V-14.5V / 2A (max)
Input  (Solar Panel) 12V-24V / 10W (min)
 

Input  (USB-C port)

PD: 5V/3A, 12V/2A, 14.5V/2A, 20V/1.45A Non-PD: 5V
 

 

Output

AC: 110V, 60Hz, 100W,  120W(peak)

QC 3.0: 3.6-6.5V/3A, 6.5-9V/2A, 9-12V/1.5A Type-C PD: 5V/3A, 12V/2A, 14.5V/2A,  20V/14.5A

Type-C Non-PD: 5V/3A

Working  Temperature 23 – 104 ˚F / -5°C – 40°C
Charging  Temperature 32 – 113 ˚F/ 0°C – 45°C
Dimension 7.3 * 6.4 * 1.6 inches
Weight 2.3 lbs.
 

AC Adaptor

Input: 100-240V, 50/60 Hz, 1.3A AC

Output: 18V=2A

DC port size 2.1mm x 5.5mm

Package Includes

  1. Power Bank
  2. AC AdaptorRENOGY 97Wh Power Bank User Manual  & troubleshooting 3

OverviewRENOGY 97Wh Power Bank User Manual  & troubleshooting 4

  1. Power Button
  2. DC Input Port
  3. USB Output Port(QC3.0)
  4. Type-C Port(PD-Output & Input)
  5. AC Output Port
  6. AC Output Indicator
  7. AC Output Switch
  8. Battery Status Indicator

LED BATTERY STATUS INDICATOR

Press the power button once to turn on the LED battery indicator. The power bank’s current charge capacity can be determined by the lights. Each blinking light represents 25% of the battery’s charge. The power bank is fully charged once the lights are no longer blinking.
First light: < 25% charged
Second light: 25%~50% charged
Third light: 50%~75% charged
Fourth light: 75%~99% charged
Please charge the power bank when the battery level is below than 25%. Over-discharging may damage the battery’s lifespan.

CHARGING THE POWER BANK

Warning: Please DO NOT charge and discharge at the same time as it could damage the battery and decrease its lifespan.
When not using original or authorized charging cables, the four LED indicators will flash at the same time, indicating that the voltage and current are not compatible with the power bank. The DC port is 2.1mm x 5.5 m.RENOGY 97Wh Power Bank User Manual  & troubleshooting 5

CHARGE OTHER DEVICESRENOGY 97Wh Power Bank User Manual  & troubleshooting 6

Note:

  1. The AC output and USB-C port cannot be used simultaneously.
  2. If your devices cannot be recognized by the USB-C port, long press the power button to turn on the 5V/3A output manually. (This function will automatically turn off if no device is connected within 15 seconds.)
  3. If the four indicators are flashing, please stop charging your devices.
  4. The power bank uses a modified sine wave and its AC output is compatible with devices under 100W.
  5. If the AC output indicator light is red, please stop using the AC appliance.

TROUBLESHOOTING

Status Cause Solution
Battery Indicators DC

Output

AC Output Indicator AC

Output

 

One indicator flashing

 

Working

 

Red light

 

Off

 

Battery level is low

 

 

Charge the power bank until at least one battery indicator is solid.

One indicator flashes twice, then turns off  

Off

Red light for 5 seconds then lights off  

Off

Battery

over-discharge protection

 

All 4 indicators are flashing

 

 

 

 

DC input port is over-voltage

 

Unplug the charger and press the power button once to recover.

 

All 4 indicators are off

 

 

 

DC input port’s voltage is too low
 

 

All 4 indicators are flashing

 

 

USB

output off

 

 

Working

 

 

Working

USB port’s output voltage/current is too high/low, or short-circuit protection is active Unplug the USB cable and press the power button once to recover.
 

 

All 4 indicators are flashing

 

 

USB-C

output off

 

 

 

 

 

 

USB-C’s output voltage/current is too high/low, or short-circuit protection is active Unplug the USB

-C cable and press the power button once to recover.

Working Red Off AC output’s voltage/current is too high/low, or short-circuit protection is active Unplug the AC cable andturn off the power bank’s AC using the switch. Then turn it on to recover.

CAUTION:

  • To prevent the power bank from capacity decrease, please unplug the AC adaptor after the power bank is fully charged.
  • Keep the product away from extreme heat or cold, as well as any flammable materials or damp places.
  • Run a full charge / discharge cycle every four months to prevent decreasing battery lifespan.
  • When not using the power bank, it is recommended to store it at 50% battery capacity.
  • Avoid charging and discharging at the same time. It could damage the battery and decrease its lifespan.
  • Using the power bank in temperatures below 32˚F or above 104˚F is not recommended as it might cause irreversible damage to the battery.
  • If any water or liquid spills on the device while using, PLEASE UNPLUG the device. Clean the device and wait until the device is completely dry before using again.

2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678
Renogy reserves the right to change the contents of this manual without notice.RENOGY 97Wh Power Bank User Manual  & troubleshooting 7

FAQ


Setting up RENOGY 97Wh Power Bank User Manual is easy with these step-by-step instructions. Follow the steps are you are set-up in no time.

Using RENOGY 97Wh Power Bank User Manual is simple by using this manual. Follow the instructions one by one and everything will be fine

Is RENOGY 97Wh Power Bank User Manual stuck or not working properly? By resetting it you can set it back to the standard settings and everything should be back to normal. This works in many cases when problems arise.

This page contains the complete user instructions & manual for RENOGY 97Wh Power Bank User Manual

All symbols, colors and codes for RENOGY 97Wh Power Bank User Manual are explained in this instruction manual. You can find everything you need and moree