ring Panic Button Z-Wave User Guide

ring Panic Button Z-Wave User Guide & troubleshooting

ring Panic Button Z-Wave User Guide  & troubleshooting 1Panic Button Z-Wave
Technical Manual

ring Panic Button Z-Wave User Guide  & troubleshooting 2

Instructions to locate Z-Wave DSK/QR code

Follow Device inclusion instructions provided in Ring Alarm mobile applications to locate QR codes and enter PIN Code

ring Panic Button Z-Wave User Guide  & troubleshooting 3

Factory Reset Instructions

Press and hold the Setup button for 10 seconds. When the LED ring stops blinking, Panic Button has reset.
A factory reset disconnects the Panic Button from your Ring Alarm. To begin using the Panic Button again, repeat the setup process in the Ring app.
Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.”

Association CC:

This sensor has one Association group of 1 node. Group 1 is the lifeline group that will receive unsolicited messages relating to Panic Button notifications, case tampering notifications, and low battery notifications.

Sensor Condition Command Class & Value Configurable?
Communication Test Notification Report, Type: System (0x09) Event: (0x05)
Wake Up Notification
Yes, via Notification Set of Notification Type 0x09
Sensor Case Removed Notification Report,
Type: Home Security (0x07)
Event: Tampering Product Covering Removed (0x03)
Wake Up Notification
Yes, via Notification Set of Notification Type 0x07, and status of
x00: This type of notification turned off OxFF: This type of notification turned on
Sensor Case Fastened Notification Report,
Type: Home Security (0x07)
Event: Previous Events Cleared (0x00)
Yes, via Notification Set of Notification Type 0x07, and status of
Ox00: This type of notification turned off OxFF: This type of notification turned on
Battery Level A level of 0x64 indicates that the battery is new.
A level of 0x63 indicates the battery is normal/ OK but not new.
A level of Ox00 indicates that the battery should be changed “soon!’ A battery level of OxFF indicates that the battery is dead and the sensor is no longer operational.
No
Panic Command Class Notification Event Type: Call Police Ox01 Yes, via Notification Set of Notification Type OxOA, and status of Ox00: This type of notification turned off OxFF: This type

To review your warranty coverage, please visit www.ring.com/warranty.
© 2020 Ring LLC or its affiliates.
Ring, Always Home, and all related logos are trademarks of Ring LLC or its affiliates.

FAQ


Setting up ring Panic Button Z-Wave User Guide is easy with these step-by-step instructions. Follow the steps are you are set-up in no time.

Using ring Panic Button Z-Wave User Guide is simple by using this manual. Follow the instructions one by one and everything will be fine

Is ring Panic Button Z-Wave User Guide stuck or not working properly? By resetting it you can set it back to the standard settings and everything should be back to normal. This works in many cases when problems arise.

This page contains the complete user instructions & manual for ring Panic Button Z-Wave User Guide

All symbols, colors and codes for ring Panic Button Z-Wave User Guide are explained in this instruction manual. You can find everything you need and moree