SLOAN Electric Powered Pedestal User Guide

SLOAN Electric Powered Pedestal User Guide & troubleshooting

SLOAN Electric Powered Pedestal User Guide  & troubleshooting 1

SLOAN Electric Powered Pedestal

SLOAN Electric Powered Pedestal User Guide  & troubleshooting 2

PARTS LIST

SLOAN Electric Powered Pedestal User Guide  & troubleshooting 3

SLOAN Electric Powered Pedestal User Guide  & troubleshooting 4

SLOAN Electric Powered Pedestal User Guide  & troubleshooting 5

IMPORTANT: Sloan added the range adjustment feature in August 2008 for faucets made prior to August 2008 use the following replacement parts: SFP-34 and SFP-8

NOT SHOWN SEPARATELY

SLOAN Electric Powered Pedestal User Guide  & troubleshooting 6

ACCESSORIES

SLOAN Electric Powered Pedestal User Guide  & troubleshooting 7

  • in Item No. column = Not shown in illustration
  • in Code No. and Part No. column = Not sold separately

TROUBLESHOOTING GUIDE

Faucet delivers water in an uncontrolled manner.
Faucet is not working properly. Contact Sloan Technical Support.

Faucet DOES NOT deliver any water when Sensor is activated.
INDICATOR: Solenoid valve produces an audible “CLICK.”
A. Water supply stop(s) closed. Open water supply stop(s).
B. Water strainer in control module is clogged. Close supply stops and remove water inlet line at control module. Remove, clean and reinstall strainer and water inlet line. Replace strainer if required.
INDICATOR: Solenoid valve DOES NOT produce an audible “CLICK.”
A. Batteries low (battery powered models). Replace batteries.
B. Power failure (adapter powered models). Check power supply.

Faucet delivers only a slow flow or dribble when Sensor is activated.
A. Water supply stop(s) are partially closed. Completely open water supply stop(s).
B. Water strainer in control module is clogged. Close supply stops and remove water inlet line at control module. Remove, clean and reinstall strainer and water inlet line. Replace strainer if required.
C. Aerator is clogged. Remove, clean, and reinstall aerator. Replace aerator if required.
D. Faucet is not working properly. Contact Sloan Technical Support.

Faucet DOES NOT stop delivering water or continues to drip after user is no longer detected.
Faucet is not working properly. Contact Sloan Technical Support.

The water temperature is too hot or too cold on a faucet connected to hot and cold supply lines.
Supply Stops are not adjusted properly. Adjust Supply Stops.

CARE AND CLEANING INSTRUCTIONS

DO NOT USE abrasive or chemical cleaners (including chlorine bleach) to clean faucet that may dull the luster and attack the chrome or special decorative finishes. Use ONLY mild soap and water, then wipe dry with clean cloth or towel.

While cleaning the bathroom tile, protect the faucet from any splattering of cleaner. Acids and cleaning fluids will discolor or remove chrome plating.

SLOAN Electric Powered Pedestal User Guide  & troubleshooting 8

FAQ


Setting up SLOAN Electric Powered Pedestal User Guide is easy with these step-by-step instructions. Follow the steps are you are set-up in no time.

Using SLOAN Electric Powered Pedestal User Guide is simple by using this manual. Follow the instructions one by one and everything will be fine

Is SLOAN Electric Powered Pedestal User Guide stuck or not working properly? By resetting it you can set it back to the standard settings and everything should be back to normal. This works in many cases when problems arise.

This page contains the complete user instructions & manual for SLOAN Electric Powered Pedestal User Guide

All symbols, colors and codes for SLOAN Electric Powered Pedestal User Guide are explained in this instruction manual. You can find everything you need and moree